Example systems engineering documents were collected from many different ITS projects to support development of this website. This view provides access to the collected examples, organized by deliverable. Note that these real world examples are not perfect, but you still may find them helpful. We are always looking for good examples, so please Contact Us if you or your agency may have additional examples to share.


Show All

Name: ADOT Loop 101 Systems Engineering Management Plan - CM Plan Excerpt
Description: This excerpt of the ADOT Loop 101 Mobility Project SEMP describes the configuration management process for the project. It covers formation of a Change Management Board, Configuration Identification, Change Control, and Status Reporting.
Project: ADOT Loop 101 Mobility Project
Access: https://www.arc-it.net/seforits/files/loop101/loop101sempNov2020excerptcm.pdf(Opens in a new window)

Name: ADOT Loop 101 Systems Engineering Management Plan
Description: The Loop 101 Mobility Project consists of multiple projects that will be planned, designed and implemented across multiple phases. The project will be complex, incorporating software acquisition and
development, hardware acquisition, field device firmware and the integration of these into a system that supports both short-term and long-term decision-making. This Systems Engineering Management Plan (SEMP) will serve as a guiding document for how the systems engineering tasks and processes will be planned and implemented.
Project: ADOT Loop 101 Mobility Project
Access: https://www.arc-it.net/seforits/files/loop101/loop101sempNov2020.pdf(Opens in a new window)

Name: ADOT Loop 101 Systems Engineering Management Plan
Description: The Loop 101 Mobility Project consists of multiple projects that will be planned, designed and implemented across multiple phases. The project will be complex, incorporating software acquisition and
development, hardware acquisition, field device firmware and the integration of these into a system that supports both short-term and long-term decision-making. This Systems Engineering Management Plan (SEMP) will serve as a guiding document for how the systems engineering tasks and processes will be planned and implemented.
Project: ADOT Loop 101 Mobility Project
Access: https://www.arc-it.net/seforits/files/loop101/loop101sempNov2020.pdf(Opens in a new window)

Name: SFpark Configuration Management Plan
Description: The configuration management plan provides the specifications and processes for recording, and managing changes to, the configuration of hardware, Commercial-off- the- Shelf (COTS) software, and communications facilities that compose the parking management system (PMS). Among other things, it is intended to prevent a situation where one vendor or person may unilaterally make a change that has negative consequences for data collection or system maintenance. It is also intended to prevent situations where a repair or change is needed for the benefit of all, but is made very difficult by inadequate documentation of the current and/or proposed configuration.
Project: San Francisco Parking Management Program (SFpark)
Access: https://www.arc-it.net/seforits/files/sfpark/sfparkcm.pdf(Opens in a new window)